| Thickness | Standards | Unit | 3 mm | 4 mm | ||
| Thickness of Aluminium Layers | [mm] | 0.5 | ||||
| Weight | [kg/m²] | 5.9 | 7.6 | |||
| Width | | [mm] | 1250 / 1500 | |||
| Technical properties | ||||||
| Section modulus | W | DIN 53293 | [cm³/m] | 1.25 | 1.75 | |
| Rigidity | E·J | DIN 53293 | [kNcm²/m] | 1250 | 2400 | |
| Alloy / Temper of Aluminium Layers | EN 573-3 EN 515 | EN AW 5005A (AIMg1) H22 / H42 | ||||
| Modulus of Elasticity | EN 1999 1-1 | [N/mm²] | 70'000 | |||
| Tensile Strength of Aluminium | EN 485-2 | [N/mm²] | Rm ≥ 130 | |||
| 0.2 % Proof Stress | EN 485-2 | [N/mm²] | Rp0,2 ≥ 90 | |||
| Elongation | EN 485-2 | [%] | A50 ≥ 5 | |||
| Linear Thermal Expansion | EN 1999 1-1 | 2.4 mm/m at 100ºC temperature difference | ||||
| Core | ||||||
Mineral-filled core | ||||||
| Surface | ||||||
| Lacquering | Coil Coating Fluorocarbon (e.g. PVDF) | |||||
| Gloss (initial value) | EN 13523-2 | [%] | 30-80 | |||
| Pencil Hardness | EN 13523-4 | HB-F | ||||
| Acoustical Properties | ||||||
| Sound Absorption Factor | αs | ISO 354 | 0.05 | |||
| Sound Transmission Loss | Rw | ISO 717-1 | [dB] | 27 | 27 | |
| Loss Factor | d | EN ISO 6721, Frequency range 100-3200 Hz | 0.004 | 0.005 | ||
| Thermal Properties | ||||||
| Thermal Resistance | R | DIN 52612 | [m²K/W] | 0.002 | 0.002 | |
| Thermal conductivity | λ | DIN 52612 | [W/mK] | 1.99 | 1.77 | |
| Heat Transition Coefficient | U | DIN 52612 | [W/m²K] | 5.83 | 5.80 | |
| Temperature Resistance | [ºC] | -50 to +80 | ||||
Wind load and permissible panel sizes
| ALUCOBOND® A2 3 mm | ALUCOBOND® A2 4 mm | |
![]() | ![]() | |
The graphs for 3 mm and 4 mm thick ALUCOBOND® A2 indicate the maximum permissible panel length (σ = 53 N/mm²) (without having to add a stiffener) based in applicable design wind load and panel width. Values apply to 4-side supported panels. Values for other systems on request.